LFY-638 material smoke toxicity test device

LFY-638 material smoke toxicity test device

LFY-638 material smoke toxicity test device

technical parameter 
1. External dimensions of the test equipment: length×width×height (1.6×0.5×1.2) m; test equipment weight: 100Kg;
2. Power supply voltage: AC 220V±10% 50 Hz, current ≤10A;
3. Maximum operating power: 1.5kW;
4. Heating power: 800-1000W;
5. Temperature control range: 300-1000℃;
6. Control accuracy: static ±1℃ (maintenance time greater than 2min);
7. Air flow: 0-20L/min adjustable;
8. Displacement rate of ring furnace: (10±0.1) mm/min.
Features 
1. Microcomputer control and computer operation;
2. Annular furnace heating temperature calibration: display time-temperature curve and actual measured temperature comparison chart;
3. The smoke density and smoke rate of the material are automatically calculated after setting;
4. Real-time display of the rotation chart of the angular velocity of the squirrel cage;
5. The running time of the ring furnace can be set arbitrarily;
6. With manual and automatic ring furnace fast forward and backward functions.
Configuration
1 computer; 2 stainless steel ring heating furnace tanks; 10 test squirrel cages; 1 set of random accessories;
Applicable standards
GB/T 20285-2006